Furnace too old to look up? Measure for the right filter
No manual online, no model number that helps, or a label too faded to read? You don't need any of that. The filter's size comes from the filter and the slot it sits in. A tape measure and two minutes are enough, and the calculator below does the rounding.
Filter size calculator
Type what you measured. Fractions like 15 3/4 or decimals like 15.75 both work. Nothing you type leaves your device.
General guidance, not a confirmed size. A tape measure gives you a good starting size. It isn't a size we've confirmed from a manufacturer document for your unit. If the new filter doesn't slide in snugly without bending, or leaves gaps, it's the wrong size.
How the calculator rounds
Filters are sold by a rounded nominal size, and the filter itself measures a little less.[1] In Parker's Airguard filter tables, each face side measures between 1/4 and 5/8 inch under its nominal size. A 16 x 25 x 1 measures 15-1/2 x 24-1/2 x 3/4, a 12 x 12 x 1 measures 11-3/4 x 11-3/4 x 3/4, and a 24 x 24 x 1 measures 23-3/8 x 23-3/8 x 3/4.[2] Trane gives the same kind of example: 15.5 x 24.5 x 0.7 is sold as 16 x 25 x 1.[3] So for a filter you measured, the calculator takes the whole inch at or just above each side.
| Sold as | Measures about | Example from the maker's table |
|---|---|---|
| 1 inch | 3/4 inch | 16 x 25 x 1 = 15-1/2 x 24-1/2 x 3/4 |
| 2 inch | 1-3/4 inch | 16 x 25 x 2 = 15-1/2 x 24-1/2 x 1-3/4 |
| 4 inch | 3-3/4 inch | 16 x 25 x 4 = 15-1/2 x 24-1/2 x 3-3/4 |
Trane's 1-inch example measures 0.7 deep.[3] For 5-inch media filters, Lennox lists its 16 x 25 x 5 and 20 x 25 x 5 Healthy Climate filters at 4-3/8 inches deep,[4] and Resideo lists a 5-inch replacement at 4.9 inches deep.[5] So the calculator reads a depth of 4-1/4 to 5-1/8 as a 5-inch filter, and flags any depth that doesn't fit one of these groups as unusual.
For an empty slot, it works the other way. The slot is the space available, and a filter measures at least about 1/4 inch under its nominal size,[2] so the calculator picks the largest whole-inch size that should still slide in. For millimeters it uses 1 inch = 25.4 mm exactly.[6] If a size isn't in the stock-size list from Parker's tables, the calculator says so. That doesn't make it wrong, but it may be a less common or custom size.
Before you start
- A rigid tape measure
- A phone camera, to photograph the old filter's frame and arrow before you throw it out
- A marker, to write the size on the cabinet when you're done
Turn the system off at the thermostat first. If you have to remove a furnace's blower door, Trane says to disconnect power before you do.[7] Common places to find the filter are a slot at the bottom of the unit, a rack on the side of the furnace, a cutout in the ductwork, or behind a return vent.[8]
Step 1: Read the size on the old filter's frame
This is the fastest answer and works on any furnace, however old. Carrier says to look for the size printed on the side of your current filter.[8] Trane says most filters have it on one or more sides.[3] If that old filter fit well, the printed size is the one to buy.[9]
- Check every edge of the frame, including the one that faced into the slot. Dust can hide the print, so wipe it.
- If you see more than one set of numbers, write them all down and photograph them. A filter has both a nominal size and an actual size.[1] Buy by the nominal one, the rounder numbers.
- If the old filter was bent, crushed or loose in the slot, don't trust its size. Measure the slot instead.
Step 2: No printed size? Measure the old filter
Trane says to measure the filter's length, width and depth with a tape measure when no size is printed.[9]
- Measure the two face dimensions. These are the long and short sides of the rectangle you see when you look at the filter. Measure the frame edge to edge.
- Measure the depth. This is the thickness. Measure the frame, not the pleats sticking out.
- Write down all three actual measurements to the nearest eighth of an inch, then put them in the calculator.
Step 3: No old filter? Measure the slot
If there's no old filter, Trane says to measure the filter compartment instead.[9] Trane's filter FAQ also mentions measuring the return opening.[1]
- Measure the inside of the opening where the filter sits, not the grille cover or the outside of the cabinet.
- Measure the width of the channel or track the filter slides into. That's the most depth the filter can have.
- A slot measurement is the space available, so it comes out a bit bigger than the filter that fits it. Pick The empty slot in the calculator, then test-fit one filter.
Old filter or slot: which is better? If the old filter fit snugly, its printed size or measurement is the best guide. If it was the wrong size, or missing, measure the slot.
Step 4: Nominal vs actual size
Every filter has two sizes. The actual size is what it really measures. The nominal size is the rounded number it's sold by.[1] Trane says the actual size might be about half an inch smaller than the size you need to buy.[3]
| Sold as (nominal) | Measures about (actual) | Source |
|---|---|---|
| 16 x 25 x 1 | 15.5 x 24.5 x 0.7 | Trane's furnace filter guide[3] |
| 12 x 12 x 1 | 11.5 x 11.5 x 0.7 | Trane's air filter FAQ[1] |
| 20 x 25 x 4 | 19-1/2 x 24-1/2 x 3-3/4 | Parker Airguard table[2] |
| 16 x 25 x 5 (Lennox Healthy Climate) | 15-3/4 x 24-3/4 x 4-3/8 | Lennox spec sheet[4] |
| 17-1/2 x 27 x 5 (Trane BAYFTFR17M replacement) | 17.3 x 26.2, 4.9 deep | Resideo spec sheet[5] |
So with standard filters, the actual measurement usually rounds up to the nominal size. Trane's example: 15.5 becomes 16, 24.5 becomes 25, and 0.7 becomes 1.[3] Trane's air-handler article simply says to round to the nearest whole number.[9] If your measurement comes out close to halfway, like 15.75, check which one slides in without forcing.
Step 5: Depth: 1 inch or thicker?
Trane says standard filters are 1 inch thick and that other types may be thicker.[9] EPA says home filters commonly come in thicknesses of 1 to 5 inches.[10]
- Thin slot, about an inch or less: round as above. A filter that measures about 0.7 is sold as 1 inch.[3]
- A box several inches deep beside or under the furnace: that's probably a media cabinet. Deep media filters have odd sizes tied to a specific cabinet. Carrier's furnace manual, for example, lists a 4-5/16-inch deep media filter for its filter cabinet.[11] Treat the calculator's answer as a starting point only. Find the part number on the cabinet door or the old filter, then check our Carrier, Trane, Goodman and Lennox pages.
Step 6: Test the fit and note the arrow
- Buy one filter first. EPA says it should fit snugly so air doesn't leak around it, and you shouldn't have to bend or crush it to fit.[10]
- Trane's owner's guide says replacement filters should be the same size as the ones originally supplied.[7]
- Filters have an arrow on the frame showing airflow. Carrier's cabinet manual says the arrows must point the way the air is moving.[12] In practice, that means away from the return duct and toward the furnace or air handler. For a wall or ceiling grille, Trane says the arrow faces into the wall, ceiling or air handler. If there's no arrow but one side has metal mesh, Trane says that side faces the return duct or the air handler.[9]
- Once it fits, write the size and the arrow direction on the cabinet with a marker, so next time takes ten seconds.
Still stuck? See how to find the model and serial label, or use the label reader on our home page. Our photo page explains what to photograph.
Last checked 2026-11-21 against the documents listed under Sources.
Sources
Every number above links to the document it came from. We re-open each one and record the date in our source log.
- Air Filters - HVAC Air Filters (FAQ: How do I find the right size air filter?), Trane (FAQ: How do I find the right size air filter?). Last checked 2026-11-18.
- Airguard MERV 10 Filters: High-Efficiency 1", 2", and 4" Pleated Extended Surface Filters (DP-M10-HC / DP-M10-SC bulletin, 1/23), Parker Hannifin Corporation (Airguard / Purolator air filtration) (DP-M10-HC and DP-M10-SC tables; DP-M10-HC table). Last checked 2026-11-21.
- Furnace Filter Guide: Everything You Need to Know, Trane (What furnace filter size do I need?). Last checked 2026-11-18.
- Healthy Climate HCC MERV 11, MERV 13, MERV 16 Media Air Cleaners for Furnaces and Air Handlers, Product Specifications (Form 210450, February 2026), Lennox Industries Inc. (p. 4). Last checked 2026-11-20.
- Replacement Filter for Perfect Fit, Specification Data 68-3070-02 (Rev. 01-22), Resideo Technologies (Honeywell Home) (Table 1 and Fig. 1). Last checked 2026-11-18.
- SI Units: Length, National Institute of Standards and Technology (NIST), Office of Weights and Measures (Standard inch). Last checked 2026-11-21.
- Owner's Guide, Indoor Units: Air Handlers, Gas Furnaces (32-5064-WEB01), Trane (p. 7). Last checked 2026-11-18.
- Need Help With Air Filters, Carrier (Canada residential site). Last checked 2026-11-18.
- Air Handler Filter Location: Where Is It?, Trane (How to get the right size filter; How to replace the HVAC air filter). Last checked 2026-11-18.
- Guide to Air Cleaners in the Home, U.S. Environmental Protection Agency (Q&A: How can I tell if the filter is the right size?). Last checked 2026-11-18.
- 59SC2D Single-Stage 4-Way Multipoise Condensing Gas Furnace, Installation, Start-up, Operating and Service and Maintenance Instructions (Catalog No. 59SC2D-04SI, edition 12/25), Carrier (p. 21, Table 9). Last checked 2026-11-18.