Coleman and Evcon mobile home furnace filter sizes

Most Coleman and Evcon downflow gas furnaces in mobile homes (the DGAA, DGAH and DGAX series) take two 16 x 20 x 1 throwaway filters in a rack on the back of the louvered door. The electric EB and EBE furnaces list a 16 x 20 x 1 filter too. The MM9E and MG9S condensing furnaces are the exception: their filters sit outside the cabinet, and the manual gives no size.

Does the model number settle it? For the DGAA, DGAH and DGAX, yes. The DGAA and DGAH installation manual gives the same door filter for every input size: two 16 x 20 x 1 filters.[1] The DGAX owner's manual says the same thing: 2 - 16 x 20 x 1.[2] The exception is a closet install with a filter grille in the door or wall. Then the filters are in that grille, not in the furnace, and the grille sets the size.[1] For the MM9E and MG9S, the model number won't settle it. Measure the filters in your return rack.

One furnace line, three brand names

These manuals are published by Johnson Controls, and their contact section sends owners to york.com.[3] The Johnson Controls document library files each of the manuals on this page under three brands: Evcon, Coleman and Guardian.[4] So a "Coleman DGAA" and an "Evcon DGAA" use the same manual. Go by the series letters at the start of the model number on the rating plate. The leading letters (DGAA, DGAX, EB, EBE and so on) are the part to match. Our model and serial label guide shows where to look.

Sizes by series

Coleman / Evcon / Guardian manufactured-housing furnace filters, from the Johnson Controls manuals cited in each row
SeriesTypeFilter the manual listsWhere it goesSource
DGAA, DGAH (56 to 90 MBH)80% gas, downflowTwo 16 x 20 x 1 throwaway filters (part S1-1214-2511)Rack on the inside of the louvered door[1][4]
DGAX80% gas, ECM blower, downflowTwo 16 x 20 x 1Rack attached to the furnace door[2]
EB (EB10F to EB23F)Electric, downflow16 x 20 x 1 (S1-1214-2511); also a 20 x 20 x 1 (S1-1214-2521) listed for the front return panelBehind the front panel[3]
EBE (EBE10A to EBE23A)Electric, downflow16 x 20 x 1 (S1-1214-2511)Behind the front panel[5]
EU, EUEElectric, upflowNo filter in the parts listBehind the return air grille, outside the furnace[3][5]
MM9E, MG9SCondensing gas, multi-positionNo size givenAlways outside the cabinet, in a rack on top of the furnace or in the return plenum[6]

The EB parts lists name two filter sizes and don't say how many of each a given furnace uses, so open the front panel and read the filters before you buy. The 20 x 20 x 1 line is tied to the front return panel, and the parts list also shows an optional front-return panel for 5-ton blower setups.[3] We won't guess beyond what the parts list says.

DGAA, DGAH and DGAX: the door rack

On these downflow gas furnaces the filters ride in a rack fixed to the back of the louvered upper door. To change them, take off the filter door and slide each filter down and out of its track. The new ones slide back in the same way, and then the door snaps back into its clips.[4]

No pleated filters in the door rack

This is the detail most people miss. Johnson Controls says the door rack is built for two standard throwaway filters only. Pleated media and washable filters can't go in it, because they create too much pressure drop and cut the airflow.[1] The owner's manuals repeat it in capitals: do not use a pleated filter in this furnace.[4][2] So for the door rack, buy plain 16 x 20 x 1 throwaway filters, not a MERV 11 or 13 pleated one. Our MERV guide explains why a finer filter restricts more air.

One line in the same owner's manual says a throwaway filter "may be replaced with cleanable filter(s)."[4] The installation manual is the more specific document. It says washable filters can't be used in the door rack and are only allowed with an external filter grille that's big enough.[1] If you're unsure, stick with the throwaway type that came with the furnace.

Closet installs with a filter grille

If your furnace sits in a closet, the return air may come through a filter grille in the closet door or wall instead. Johnson Controls allows that only for closet installs. The grille has to be within 12 inches of the furnace's return opening, with at least 6 inches between the furnace front and the door or grille. When a grille like that is used, the filters inside the furnace door are taken out.[1] So if you open the furnace door and find an empty rack, look for a grille before you assume something's missing.

The manual also sets a minimum size for that grille. With throwaway filters it needs at least 540 square inches, which is a 15 x 36 grille. With pleated or washable filters it needs at least 684 square inches, an 18 x 38 grille.[1] The bigger grille is there to make up for the extra pressure drop. The filter size is whatever fits your grille, so measure the grille's filter or check the label on the filter in it.

EB and EBE electric furnaces

On the downflow electric models you take off the furnace's front panel to reach the filter. On the upflow EU and EUE, the filter isn't in the furnace at all. It's behind the return air grille next to the furnace closet, or somewhere else in the return.[3][5] That fits the parts lists: the EB and EBE lists include filters, and the EU and EUE lists don't.[3][5] The electric furnaces ship with a throwaway filter.[5]

MM9E and MG9S condensing furnaces

These condensing furnaces work differently. The manual says their filters have to be installed outside the furnace casing and never inside the cabinet.[6] In a manufactured or modular home with a downflow install, it describes two setups:

The manual tells you to replace them with filters the same size as the ones you take out, but it doesn't print a size.[6] Read the size on the old filters' frames, or measure the rack.

How often to check

For the DGAA, DGAH and DGAX, Johnson Controls says to check the filters every 3 months. In a newly built home, check every week for the first four weeks and then every three weeks, especially if the fan runs all the time.[4] A clogged filter chokes the airflow, and the manual warns it can overheat the heat exchanger and blower motor.[4]

Reading these sizes

Other mobile home furnaces

We've only checked the Johnson Controls manuals listed here. Older Evcon series that aren't covered (such as the DGAT and DGAM) have their own manuals, so don't assume they match. For Intertherm, Miller and Nordyne furnaces, see our Nordyne page. For any other furnace, our find your filter size guide works. Other brands: Carrier, Trane, Goodman and Amana, Lennox, Rheem and Ruud.

Last checked 2026-11-23 against the documents listed under Sources.

Sources

Every number above links to the document it came from. We re-open each one and record the date in our source log.

  1. Installation Manual: Sealed Combustion Gas Furnace, Models DGAA and DGAH, single stage downflow (129098-UIM-L-0516), Johnson Controls Unitary Products (document hosted by Winstel Controls) (p. 9, Table 3; p. 9, Section IV; p. 9, Section IV, Downflow Filters; p. 9, Section IV, items a and b). Last checked 2026-11-23.
  2. User's Information Manual: DGAX Series 80% AFUE single-stage ECM downflow gas furnace (5483103-UUM-A-1118), Johnson Controls Ducted Systems (docs.johnsoncontrols.com; library lists brands Evcon, Coleman, Guardian) (p. 5, Air Filters). Last checked 2026-11-23.
  3. User's Information, Maintenance and Service Manual: EB/EU Series downflow/upflow electric furnace (5393807-BUM-B-0818), Johnson Controls Ducted Systems (docs.johnsoncontrols.com; library lists brands Evcon, Coleman, Guardian) (p. 1, Contact Information; p. 3, Filter Location; pp. 5-6, parts lists; p. 3, Filter Location; pp. 8-9; pp. 5-6, parts lists; p. 3, Filter Location; pp. 5-6 and 8-9, parts lists). Last checked 2026-11-23.
  4. User's Information Manual: DGAA and DGAH Series 80% AFUE single-stage downflow gas furnace (5165697-BUM-C-0818), Johnson Controls Ducted Systems (docs.johnsoncontrols.com; library lists brands Evcon, Coleman, Guardian) (library listing: brands Evcon, Coleman, Guardian; pp. 9-10, parts list item 16; p. 5, Removing Filters; p. 5, Air Filters). Last checked 2026-11-23.
  5. User's Information Manual: EBE and EUE Series downflow/upflow electric furnace (5396714-BUM-C-0919), Johnson Controls Ducted Systems (docs.johnsoncontrols.com; library lists brands Evcon, Coleman, Guardian) (p. 3, Filter Location; pp. 6-7, parts lists item 3; p. 3, Filter Location; pp. 9-10; p. 3, Filter Location; pp. 6-7 and 9-10, parts lists; p. 3, Air Filter). Last checked 2026-11-23.
  6. User's Information Manual: MM9E and MG9S Series 33-inch multi-position gas furnaces, manufactured housing or modular (5165698-UUM-C-0519), Johnson Controls Ducted Systems (docs.johnsoncontrols.com; library lists brands Evcon, Coleman, Guardian) (p. 4, External Air Filters; p. 4). Last checked 2026-11-23.
  7. Furnace Filter Guide: Everything You Need to Know, Trane (What furnace filter size do I need?). Last checked 2026-11-18.