Intertherm, Miller and Nordyne mobile home furnace filter sizes
Intertherm and Miller are brand names on Nordyne's mobile home furnaces. On these downflow furnaces the filter size depends less on the model and more on where the return air comes in: through the louvered front door, through the top, or through a side kit. Nordyne's manuals give exact sizes for the top-return and side-return setups. For the front-door filter they give only a part number.
Does the model number settle it? Only partly. On the M7RL, the last letters of the model number tell you the return type. Models ending in AW or BW take return air through the front louvered door. Models ending in AWT or BWT take it through the top.[1] A top-return furnace ships with an 18 x 18 x 1 filter.[1] A front-return furnace ships with a reusable filter clipped inside the door, and the manual doesn't print a size for it.[1] If yours is a front-return unit, or if someone has changed the return setup, read the filter that's in there now or measure the space.
Same furnace, several brand names
Nordyne's own reference guide for manufactured housing lists the same furnace series under several brand names. The M1, M7RL, MG2R and MG2S series appear under Broan, Intertherm, Maytag and Miller. The M2 series appears under Intertherm and Miller.[2] So an "Intertherm M7RL" and a "Miller M7RL" use the same manual. Go by the series letters on the rating plate, not the name on the door. Our model and serial label guide shows how to find that plate.
Step 1: work out which way the return air comes in
- Front return (louvered door). Air comes in through the slots in the furnace door, and the filter sits on the inside of that door. On the M7RL these are the AW and BW models.[1] On the MG2R the code is an F right after the input rate in the model number.[3]
- Top return. The return duct comes into the top of the furnace, and the door has no louvers. On the M7RL these are the AWT and BWT models.[1] On the MG2R the code is a T after the input rate.[3] The M7RL parts list shows a louvered door for front-return models and a non-louvered door for top-return models.[4]
- Side return (field kit). A front-return furnace can be converted so the return duct connects to the side of the cabinet with kit PN 904003.[1] The kit swaps in a front door without louvers and adds a filter frame on the side.[5] A plain door with a filter frame on the side of the cabinet usually means this kit was installed.
Step 2: match the return type to the filter size
| Return type | What the manual says ships or fits | Where it goes |
|---|---|---|
| Top return (M7RL AWT/BWT, MG2R with T, MG2S top return) | One disposable 18 x 18 x 1 filter (M7RL part 669779) | Inside the blower compartment, angled over the blower and held by a U-shaped retainer |
| Side return (kit 904003) | 20 x 20 x 1 filter | In the filter frame on the side of the cabinet |
| Front return (M7RL AW/BW, MG2R with F, MG2S front return) | One reusable filter. No size printed in the manual | Held to the inside of the louvered door by a retaining bracket |
The MG2R manual gives the same three cases: 18 x 18 x 1 for top return, 20 x 20 x 1 for side return, and a reusable door filter for front return.[3] So does the MG2S manual.[6] The side return kit's own instructions list a 20 x 20 filter frame and a 20 x 20 filter, and say the kit is for M3, M7 and MG2S furnaces.[5]
Top return: put the filter in the right way
On a top-return M7RL, the filter slides in between the combustion air pipe and the blower, gets pushed to the back of the cabinet, and is angled up over the blower. Then the U-shaped retainer holds it in place. The airflow arrows on the filter should point toward the blower assembly.[1] The manual also says that on a top-return install, an external or in-wall filter mount can be used instead. In that case the factory filter comes out.[1] If you open the blower compartment and find no filter, check for a filter grille in a wall or ceiling before you buy one.
Front return: why there's no size to copy
For front-return models the parts list gives the door filter as part 669363 on the 045, 060 and 072 sizes of the M7RL.[4] It doesn't list dimensions, and neither does the installation manual.[1] You can order the part by number from a parts dealer. Or take the old filter off the door and measure its length, width and thickness, then compare with our measuring guide. We're not going to guess at a door-filter size the manual doesn't give.
Older M1 series furnaces (M1G, M1M, M1S, M1B)
The M1 is an older Nordyne downflow, direct-vent furnace built for manufactured homes. Its installation manual says the furnace is meant only for free return air through the louvers in the furnace door, and that a ducted return must not be connected straight to the furnace.[7] So the filter is behind the door louvers. Nordyne's parts list gives the same two parts for every M1G, M1M, M1S and M1B model it covers, and for the M5S oil furnace: air filter 669064 and filter retainer wire 669065.[8] Like the M7RL door filter, the parts list gives no dimensions. Use the part number, or measure the filter that's on your door.
Because the parts list pairs the filter with a retainer wire, look on the inside of the door for a wire that holds the filter in place. That's where the replacement goes.
M2R series (condensing manufactured home furnaces)
Nordyne's M2R parts list covers the M2RC upflow and M2RL downflow condensing furnaces for manufactured homes.[9] It's the one Nordyne parts list we checked that prints filter dimensions.
| Series | Input sizes listed | Filter listed | Part number |
|---|---|---|---|
| M2RC upflow | 80,000 and 100,000 BTUH | 18 5/8 x 26 1/2 x 1/4 | 669300 |
| M2RL downflow | 60,000, 80,000 and 100,000 BTUH | 18 x 20 x 1 | 668860 |
The upflow M2RC filter is a thin 1/4-inch pad, not a standard 1-inch filter. The parts list doesn't say whether these are nominal or actual dimensions, so check them against the filter you take out.
Reading these sizes
- 18 x 18 x 1 and 20 x 20 x 1 are store sizes. Filters are sold by a rounded nominal size, and the actual filter is a little smaller.[10] The manuals don't say which they mean, so compare with the filter you pull out.
- How often. Nordyne's M7RL manual recommends cleaning or replacing the filter monthly, and more often in a new or freshly remodeled home while construction dust settles.[1]
- Never run it without one. The manual warns that dust building up inside can cost efficiency, damage the equipment, and create a fire risk.[1] A thicker or finer filter can also restrict airflow. See MERV ratings before you go up in rating on a thin door filter.
Other mobile home furnaces
We've only checked the Nordyne documents listed above. Coleman and Evcon furnaces have their own manuals; see our Coleman and Evcon page. The same goes for Nordyne series not covered here, like the MG1, MG3 and the electric E-series. Don't assume they use these sizes. Our find your filter size guide works for any furnace. Other brands: Carrier, Trane, Goodman and Amana, Lennox, Rheem and Ruud.
Last checked 2026-11-22 against the documents listed under Sources.
Sources
Every number above links to the document it came from. We re-open each one and record the date in our source log.
- M7RL Series Downflow Condensing Gas Furnace 95.1% AFUE, Installation Instructions (709404D, replaces 709404C, 04/18), Nortek Global HVAC (Nordyne literature library, Miller brand) (p. 11, Return Air Connections; p. 12, Furnace Filter; pp. 11-12, Return Air Connections and Furnace Filter; p. 12, Furnace Filter, steps 1-4; p. 11, note on top return installations; p. 12, Warning). Last checked 2026-11-22.
- Manufactured Housing Models & Brands Reference, Nordyne / Nortek Global HVAC (Nordyne literature library) (p. 7, Gas Furnace). Last checked 2026-11-22.
- MG2R Series Downflow Condensing Gas Furnace 95% AFUE, Installation Instructions (10502180, 03/25), Nordyne LLC (Nordyne literature library, Miller brand) (p. 11, Return Air Connections; p. 11, Return Air Connections; p. 12, Furnace Filter). Last checked 2026-11-22.
- M7RL Series 95.1% AFUE Single Stage Condensing Downflow Gas Furnace, Replacement Parts List (709265H, replaces 709265G, 03/16), Nortek Global HVAC (Nordyne literature library, Miller brand) (p. 2, items 1 and 2; p. 2, item 3). Last checked 2026-11-22.
- Side Return Air Kit (#904003) for M3 / M7 / MG2S Furnaces, Installation Instructions (708170B, replaces 708170A, 02/19), Nortek Global HVAC (Nordyne literature library, Miller brand) (p. 1, kit contents; p. 1). Last checked 2026-11-22.
- MG2S Series Downflow Condensing Gas Furnace 96+% AFUE, Two-Stage, Installation Instructions (10502260, 03/25), Nordyne LLC (Nordyne literature library, Miller brand) (p. 11, Return Air Connections; p. 12, Furnace Filter). Last checked 2026-11-22.
- M1M Series Downflow, Direct Vent (Sealed Combustion) Forced Air Gas Furnaces, Installation Instructions (10187000, 03/18), Nortek Global HVAC (Nordyne literature library, Miller brand) (p. 6). Last checked 2026-11-22.
- Replacement Parts List, M1G(*), M1M(*), M1S,B(*), M1S(*) and M5S(B,C) Series Direct Vent Forced Air Gas and Oil Furnaces (707977K, replaces 707977J, 02/23), Nortek Global HVAC (Nordyne literature library, Miller brand) (p. 2, p. 3 and p. 6, items 7 and 8). Last checked 2026-11-22.
- Replacement Parts List, Manufactured Home Furnaces, M2R Series (708072A, replaces 7080720, 06/15), Nortek Global HVAC (Nordyne literature library, Miller brand) (p. 1 and p. 3, title and contents; p. 4 and p. 6, item 18). Last checked 2026-11-22.
- Furnace Filter Guide: Everything You Need to Know, Trane (What furnace filter size do I need?). Last checked 2026-11-18.